Products

+GF+ Fuseal Schedule 40 and 80 Polypro Pipe

Main Image

FLAME RETARDANT, ACID RESISTANT ACID WASTE SYSTEM FOR NON-PRESSURE APPLICATIONS
Fuseal, the proven resistance coil fusion method of joining polypropylene drain piping systems. Used primarily for acid waste drain lines. Fuseal has been utilized in thousands of institutional and industrial projects that demand strong, leak-proof, safe pipe joints.

The Fuseal heat fusion process joins pipe and fitting into one complete homogenous unit. A low voltage Fuseal power unit is connected to an electrical resistance coil imbedded in the Fuseal fitting. When power is applied the coil heat completely fuses the interface between the pipe and fitting socket. The complete line of fittings include all standard DWV configuration in 1 1/2″ through 12″ pipe sizes.

Pipe is readily available in flame-retardant Schedule 40/80, non-flame retardant Schedule 40/80. The Fuseal heat fusion method should be used in inaccessible places where a completely homogenous structure of pipe and fitting is essential. The mechanical system can be used under bench where speed of installation, future disassembly or modular design is desired. Fittings 1 1/2″ through 6″ are manufactured of flame retardant material but 8″ and above are manufactured of non-flame retardant material. Made of polypropylene and PVDF, the Fu seal II system combines to provide a complete, easy to install corrosive and chemical waste drainage system.

• Corrosive waste drainage system
• Chemical plants
• Industrial plants
• Hospitals
• University laboratories

1 1/2″ – 6″ Available in 20′ lengths upon request

SIZE (IN) LENGTHS (FT) PART NUMBER LIFT QUANTITY (FT) AVERAGE OD (IN) MIN. WALL (IN)
SCHEDULE 40 FIRE RETARDANT PIPE**
1 1/2 10 *37A013015 1800 1.9 0.145
2 10 *37A013020 1050 2.375 0.154
3 10 *37A013030 580 3.5 0.216
4 10 *37A013040 510 4.5 0.237
6 10 *37A013060 220 6.625 0.28
8 20 *37A013080 280 8.625 0.322
10 20 *37A013100 220 10.75 0.365
12 20 *37A013120 100 12.75 0.406
SIZE (IN) LENGTHS (FT) PART NUMBER LIFT 11UANTITY (FT) AVERAGE OD (IN) MIN. WALL (IN)
SCHEDULE 40 NDN FIRE RETARDANT PIPE
1 1/2 20 *37B023015 3600 1.9 0.145
2 20 *37B023020 2100 2.375 0.154
3 20 *37B023030 1160 3.5 0.216
4 20 *37B023040 1020 4.5 0.237
6 20 *37B023060 440 6.625 0.28
8 20 *37B023080 280 8.625 0.322
10 20 *37B023100 220 10.75 0.365
12 20 *37B023120 100 12.75 0.406
14 20 *37B023140 100 14 0.437
16 20 *37B023160 100 16 0.5
18 20 *37B023180 60 18 0.562
SIZE (IN) LENGTHS (FT) PART NUMBER LIFT 11UANTITY (FT) AVERAGE OD (IN) MIN. WALL (IN)
SCHEDULE 80 NDN FIRE RETARDANT PIPE
1 1/2 20 *37B021015 3600 1.9 0.2
2 20 *37B021020 2100 2.375 0.281
3 20 *37B021030 1160 3.5 0.3
4 20 *37B021040 1020 4.5 0.337
6 20 *37B021060 440 6.625 0.432
8 20 *37B021080 280 8.625 0.5
10 20 *37B021100 220 10.75 0.593
12 20 *37B021120 100 12.75 0.687